SF100 RSST

Operating Voltage Range . . . . . . . . . . . . . . . . . . . 20-28VDC Maximal consumption (main tone type 27): - low volume level, with enabled strobe . . . . 12mA @ 24VDC - low volume level, no strobe . . . . . . . . . . . 8.5mA @ 24VDC - high volume level, with enabled strobe. . . . 25mA @ 24VDC - high volume level, no strobe . . . . . . . . . . . 22mA @ 24VDC Sound volume (main tone type 27): - low volume . . . . . . . . . . . . . . . . . . . . . . . 84-93dB @ 1m - high volume . . . . . . . . . . . . . . . . . . . . . . 92-101dB @ 1m Frequency of the strobe flashing . . . . . . . . . . . . . . 1Hz Sounder type . . . . . . . . . . . . . . . . . . . . . . . . . . . Piezo Number of tone types . . . . . . . . . . . . . . . . . . . . . 32 Wire Gauge for terminals . . . . . . . . . . . . . . . . . . . 0.2-1.5mm2 Operating temperature . . . . . . . . . . . . . . . . . . . . . -10°C to +60°C Relative humidity resistance . . . . . . . . . . . . . . . . . (93 ± 3)% @ 40°C Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP21C Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ~248g Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102x32mm Color . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . red Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAN, transparent red

رمز المنتج : SF100 RSST
تفاصيل المنتج
المتوفر بالمقاسات :

منتجات مماثلة

منتجات مماثلة مقترحة

MAG2P

mag2p

MAG2P

Main Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . ~230  ± 10% Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/ 60Hz Back-up Power Supply . . . . . . . . . . . . . . . . . . . . . . 1 battery, 12V/ 7Ah Power availability . . . . . . . . . . . . . . . . . . . . . . . . . . 0.7A Main power supply fail consumption. . . . . . . . . . . . . 50mA Outputs (sounder circuits on the control PCB module) . . . 2; 24V/ 0.3A fuse Output, FAULT Relay . . . . . . . . . . . . . . . . . . . . . . . . 1; 3A@120VAC;  3A@60VDC Output, FIRE Relay . . . . . . . . . . . . . . . . . . . . . . . . . 1; 3A@120VAC;  3A@60VDC Auxiliary output . . . . . . . . . . . . . . . . . . . . . . . . . . . 24VDC/ 0.3A fuse Fixed zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Detectors per zone /  max. number of detectors . . . . . 32/ 64 Multi language front panels . . . . . . . . . . . . . . . . . . . YES Operating temperature . . . . . . . . . . . . . . . . . . . . . . 0°C to +40°C Relative humidity resistance . . . . . . . . . . . . . . . . . . (93 ± 3)% @ 40°C Weight (without battery) . . . . . . . . . . . . . . . . . . . . . ~2.1kg Dimensions of the plastic box . . . . . . . . . . . . . . . . . 340x290x100mm
MAG 4

mag-4

MAG 4

Main Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . ~230  ± 10% Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/ 60Hz Back-up Power Supply . . . . . . . . . . . . . . . . . . . . . . 1 battery, 12V/ 7Ah Power availability . . . . . . . . . . . . . . . . . . . . . . . . . . 0.7A Main power supply fail consumption. . . . . . . . . . . . . 50mA Outputs (sounder circuits on the control PCB module) . . . 2; 24V/ 0.3A fuse Output, FAULT Relay . . . . . . . . . . . . . . . . . . . . . . . . 1; 3A@120VAC;  3A@60VDC Output, FIRE Relay . . . . . . . . . . . . . . . . . . . . . . . . . 1; 3A@120VAC;  3A@60VDC Auxiliary output . . . . . . . . . . . . . . . . . . . . . . . . . . . 24VDC/ 0.3A fuse Fixed zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Detectors per zone /  max. number of detectors . . . . . 32/ 128 Multi language front panels . . . . . . . . . . . . . . . . . . . YES Operating temperature . . . . . . . . . . . . . . . . . . . . . . 0°C to +40°C Relative humidity resistance . . . . . . . . . . . . . . . . . . (93 ± 3)% @ 40°C Weight (without battery) . . . . . . . . . . . . . . . . . . . . . ~3.5kg Dimensions of the metal box . . . . . . . . . . . . . . . . . . 320x220x80mm
MAG 8

mag-8

MAG 8

Main Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . ~230VAC ± 10% Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/ 60Hz Back-up Power Supply . . . . . . . . . . . . . . . . . . . . . . 1 battery, 12V/ 7Ah Power availability . . . . . . . . . . . . . . . . . . . . . . . . . . 0.7A Main power supply fail consumption. . . . . . . . . . . . . 125mA Outputs (sounder circuits on the control PCB module) . . . 2; 24V/ 0.5A fuse Output, FAULT Relay . . . . . . . . . . . . . . . . . . . . . . . . 1; 3A@24VDC Output, FIRE Relay . . . . . . . . . . . . . . . . . . . . . . . . . 1; 3A@24VDC Auxiliary output . . . . . . . . . . . . . . . . . . . . . . . . . . . 24VDC/ 0.3A fuse Fixed zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Detectors per zone / max. number of detectors . . . . . 32/ 256 Multi language front panels . . . . . . . . . . . . . . . . . . . YES Operating temperature . . . . . . . . . . . . . . . . . . . . . . 0°C to +40°C Relative humidity resistance . . . . . . . . . . . . . . . . . . (93 ± 3)% @ 40°C Weight (without battery) . . . . . . . . . . . . . . . . . . . . . ~2.4kg Dimensions of plastic box . . . . . . . . . . . . . . . . . . . . 340x290x100mm